Manual
1X UBS Macro B T S FRU P ack et B T S shutdown procedures
Procedure 3 -2 Shutdown site signaling functions procedure for a pack et B T S
(Continued)
6
A fter all parameters are entered, the system displays the command to
be sent and the prompt below . V erify the command syntax is correct.
omc-000000>Accept [yes/no]?
7
A t the prompt shown in step 6 , enter Y to accept the command or N to go bottom and enter
the correct value(s).
8
Enter the following command at the prompt to display the status of the signaling REDIRECT
parameters to verify that the applicable BTS is ready for global redirect:
omc-000000> DISPLAY BTS-<bts#> REDIRECT
9
Ensure that the values in the system display response match the values input in step 5 .
10
Enter the following command at the prompt to display the status of the BTS signaling redirect
parameters for all carriers equipped for the BTS:
omc-000000> DISPLAY BTS-<bts#> REDIRECT2
1 1
Record the values shown in the system display response resulting from step 10 .
These values are used to answer the prompts for the EDIT BTS REDIRECT2
command when restoring signaling operations at the end of the replacement
procedure.
12
This step edits the REDIRECT2 parameters so that the Global Service Redirect
Message to be broadcast on the paging channel redirects all subscribers away from
the BTS with the failed equipment and onto a CDMA channel at a neighbor site.
Enter the following command at the prompt:
omc-000000> EDIT BTS-<bts#> REDIRECT2!
The system prompts to enter each command parameter value one at a time. Answer the
prompts in the following order:
expecting an integer number (from 0 to 65535)
<EXPNID= ?>
Continued
68P09283A64 -3 3 -7
FOA SEP 2007