Ov erview Chapter 1: Introduction and Fr ame Identication
Chapter 2 – UBS Macro BTS installation procedure
This chapter provides figures showing the location of all UBS Macro connectors for external
cabling and wiring purposes, external cable run list, and a detailed installation sequence.
Installation procedures cover mounting items to the rack and installing the external cabling.
Chapter 3 - Low -to -Mid Capacity Frame Expansion Procedures
This chapter provides information and procedures needed for expanding the low -capacity UBS
Macro BTS starter/expansion frame to the mid -capacity frame configuration.
Chapter 4 - What’s next
This chapter provides procedures for cleaning up the site and the installation completion
checklist.
Equipment shipped assembled
The low -capacity , +27 V DC UBS Macro BTS is shipped pre -assembled on carrier strips with
all internal cabling installed. This pre -assembled equipment is delivered in a crate. A fter the
crate is unpacked, the low -capacity +27 V DC UBS Macro BTS assembly is ready to be rack
mounted. The carrier strips allow four people to carefully lift the assembly off the crate packing
onto the rack. The assembly can also be lifted via some mechanical aid (hoist, etc.) attached
to the lifting loops on the ends of the carrier strips. The carrier strips also provide easy rack
mounting. A fter the UBS Macro equipment is rack mounted, cables are connected between the
UBS Macro equipment and external site inputs/outputs.
Equipment shipped un -assembled
The low -to -mid capacity expansion equipment and associated cables are shipped in separate
individual containers. The additional expansion equipment is mounted into the low -capacity
frame and then the associated interconnect cables are installed.
F or -48 V DC or 220 V AC UBS Macro BTS applications, either a -48 V DC or a 220 V AC PSM
(P ower Supply Module) shelf is required. The PSM shelf comes assembled, but without PSMs
installed in the shelf . F or a low capacity frame, either two -48 V DC or two 220 V AC PSMs are
installed in the shelf . The second PSM is for redundancy . The PSM shelf without PSMs is
delivered in a single box. Each PSM is delivered in a single box. The PSM shelf is mounted at
the bottom of the rack. Then the PSMs are installed in the PSM shelf . The +27 V DC UBS Macro
assembly is mounted just above the PSM shelf . The PSM +27 V DC output cable is connected to
the +27 V DC input cable on the +27 V DC UBS Macro assembly . The site -48 V DC or 220 V AC
power source is cabled/wired to the PSM shelf .
The Remote GPS (RGPS) head and associated cable are shipped un -assembled. The cable has to
be connected to the RGPS head along with the customer supplied mounting mast.
Most of the cable/wire connectors that are required to connect with the UBS Macro equipment
external site input/output connectors are supplied, but need to be assembled onto cables/wires.
Most of the cables/wires are supplied by the customer .
1 -6 68P09283A62 -3