User Manual
R equired T est Equipment and Softw are Chapter 1: Introduction
RS–232 to GPIB Interface
• National Instruments GPIB–232CT–A is used to interface the LMF to the test equipment.
• Standard RS–232 cable can be used with the following modifications (see Figure 1 -1 )
This solution passes only the 3 minimum electrical connections between the LMF
and the General Purpose Information Bus (GPIB) interface. The control signals are
jumpered as enabled on both ends of the RS–232 cable (9–pin D). TX and RX signals
are crossed as Null Modem effect. Pin 5 is the ground reference.
Short pins 7 and 8 together , and short pins 1, 4, and 6 together on each connector .
Figure 1 -1 Null Modem Cable Detail
ti-cdma-00088.eps
5
3
2
7
8
1
4
6
GND
RX
TX
RTS
CTS
RSD/DCD
DTR
GND
TX
RX
RTS
CTS
RSD/DCD
DTR
5
2
3
7
8
1
4
6
DSR
DSR
FW00362
9-PIN D-FEMALE 9-PIN D-FEMALE
ON BOTH CONNECTORS
SHORT PINS 7, 8;
SHORT PINS 1, 4, AND 6
Communications System Analyzer CDMA/Analog
Table 1 -1 CDMA LMF T est Equipment Support T able
Item Description
T est Capability
T est Sets
Agilent 8935 (formerly HP8935)
Communication T est Set CDMA 2000 T esting
Agilent E4406A (with E4432B) Communications Analyzer with Agilent
E4432B CDMA Signal Generator
CDMA 2000 testing
Advantest R3267 Analyzer (with
R3562)
Communications Analyzer with Advantest
R3562 Generator
CDMA 2000 testing
Agilent E7495A/B
Communications test set CDMA 2000 testing
Anritsu™ MT8212B
Multi-purpose test set
CDMA 2000 testing
P ower Meters
Gigatronix 8541C
P ower Meter
Agilent E4418
P ower Meter
1 -10 68P09283A63 -5