1X UBS Macro B T S Optimization/A TP R equired T est Equipment and Softw are
Required Test Equipment and Software
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■
■
Overview
T est equipment and software described in this section is required for the calibration and
acceptance testing procedures. Common tools such as screwdrivers and frame keys are also
needed. Read the operators manual for all test equipment items to understand their individual
operation before using them for calibration or acceptance testing.
LMF Computer and Software
LMF Hardware Requirements
An LMF computer platform that meets the following minimum requirements (or better) is
recommended:
• 533 MHz (1 GHz or higher recommended) P entium processor
• W indows 2000 or W indows XP operating system
• 4 GB internal hard disk drive or larger
• Color display with 1024 x 768
• Memory requirements: 256 MB (500 MB recommended)
• CD/D VD drive
• Serial port COM 1
• Serial port COM 2 for SC™6XX and serial versions of SC™3XX
• Ethernet Hub or Switch (recommended with 10Base2 port, for example 3Com®
OfficeConnect® Ethernet Hub 4C) 10Base2/10BaseT Converter (only if switch doesn’t
have 10Base2 port, for example Unicom ETP -20038T)
LMF Software
The Local Maintenance F acility (LMF) application program is a graphical user interface
(GUI)–based software tool. This product is specifically designed to provide cellular
communications field personnel with the capability to support the following UBS operations:
• Installation
• Maintenance
• Calibration