User's Manual
Power Delta Calibration68P09258A31–A
Oct 2003
1X SCt 4812T BTS Optimization/ATP
H-5
Figure H-2: Delta Calibration Setup – HP8921A to HP8921A
Measurement HP8921A
Source HP8921A
Short RF Cable
DUPLEX
OUT
RF
IN/OUT
FW00802
Advantest R3465 Power Delta Calibration
Follow the procedure in Table H-2 to perform the Advantest R3465
Power Delta Calibration procedure.
Table H-2: Advantest Power Delta Calibration Procedure
Step Action
NOTE
Perform this procedure after test equipment has been allowed to warm–up and stabilize for a minimum
of 60 minutes.
On the Advantest R3465:
1 Press the SHIFT and the PRESET keys located below the CRT display.
2 Press the ADVANCE key in the Measurement area of the control panel.
3 Press the CDMA Sig CRT menu key.
4 Press the FREQ key in the Entry area of the control panel.
5 Set the frequency to the desired value using the keypad entry keys.
6 Press the LEVEL key in the Entry area of the control panel.
7 Set the LEVEL to 0 dBm using the keypad entry keys.
8 Verify the Mod CRT menu key is highlighting OFF, if not press the Mod key to toggle it OFF.
9 Verify the Output CRT menu key is highlighting OFF. If not, press the Output key to toggle it OFF.
On the HP 437 Power Meter:
10 Zero the Power Meter prior to connecting the power sensor to the RF cable from the signal generator.
NOTE
For best accuracy, always re–zero the power meter before connecting the power sensor to the
component being calibrated.
11 Connect the RF cable from the R3561L CDMA Test Source Unit RF OUT port to the power sensor
(see Figure H-3).
12 Press the Output CRT menu key to toggle the Output to ON.
. . . continued on next page
H