Bay Level Offset Calibration
68P09258A31–A
Oct 2003
1X SCt 4812T BTS Optimization/ATP
3-98
Table 3-40: All Cal/Audit Test
n ActionStep
9 Follow the cable connection directions as they are displayed. A status report window displays the
test results.
10 Click on Save Results or Dismiss to close the status report window.
Create CAL File
The Create Cal File function gets the BLO data from BBXs and
creates/updates the CAL file for the BTS. If a CAL file does not exist, a
new one is created. If a CAL file already exists, it is updated. After a
BTS has been fully optimized, a copy of the CAL file must exist so it
can be transferred to the CBSC. If TX calibration has been successfully
performed for all BBXs and BLO data has been downloaded, a CAL file
exists. Note the following:
S The Create Cal File function only applies to selected (highlighted)
BBXs.
WARNING
The user is not encouraged to edit the CAL file as this action can
cause interface problems between the BTS and the LMF. To
manually edit the CAL file, you must first logout of the BTS. If
you manually edit the CAL file and then use the Create Cal File
function, the edited information is lost.
Prerequisites
Before running this test, the following should be done:
S LMF is logged into the BTS.
S BBXs are OOS_RAM with BLO downloaded.
Creating a CAL File
Table 3-41: Create CAL File
n Step Action
1 Select the applicable BBXs.
NOTE
The CAL file is only updated for the selected BBXs.
2 Click on the Device menu.
3 Click on the Create Cal File menu item. A status report
window displays the results of the action.
4 Click OK to close the status report window.