User's Manual Part 4

Compact BTS Expansion Configuration (Indoor) – continued
MAY 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU E-3
PRELIMINARY
Starter and Three Expansion
BTSes Interconnect Cabling for
Dual cCLPA
Table E-3 shows in tabular format the interconnect cabling of
Figure E-1.
Table E-3: Starter and Three Expansion BTS Interconnect Cabling
for Circuit or Packet Configuration with Dual cCLPA
BTS Expansion 1 Expansion 2 Expansion 3 cCLPA
Starter TX–1 cCLPA–1 (TX IN)
Starter TX–2 cCLPA–2 (TX IN)
Starter EXP–TX 2 EXP TX–2 *cCLPA–2
Starter EXP–TX 3 EXP TX–2 *cCLPA–1
Starter EXP–TX 4 EXP TX–2 *cCLPA–2
Starter RX MAIN cCLPA–1
(RX OUT)
Starter EXP–RX MAIN 2 EXP – RX
MAIN 2
*cCLPA–1
Starter EXP–RX MAIN 3 EXP – RX
MAIN 2
*cCLPA–2
Starter EXP–RX MAIN 4 EXP – RX
MAIN 2
*cCLPA–2
Starter RX DIV cCLPA–2
(RX OUT)
Starter EXP–RX DIV 2 EXP – RX DIV
2
*cCLPA–2
Starter EXP–RX DIV 3 EXP – RX DIV
2
*cCLPA–1
Starter EXP–RX DIV 4 EXP – RX DIV
2
*cCLPA–2
Starter SDCX 2 SDC INPUT
EXPANSION
Starter SDCX 3 SDC INPUT
EXPANSION
Starter SDCX 4 SDC INPUT
EXPANSION
* Not actual physical connections to cCLPA, but software connections through the Starter BTS.
E