User's Manual Part 4
MCC–DO Tests – continued
PRELIMINARY
1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU MAY 2004
A-12
Table A-5: Procedure to Test MCC–DO Packet Error Rate
Step Action
9 Connect an MMI cable to the MCC–DO card.
10 Open a HyperTerminal application.
11 Open the COM to the MCC–DO MMI. Set parameters as follows:
S Bits per second: 9600
S Data bits: 8
S Parity: None
S Stop bits: 1
S Flow control: None
12 When the login prompt appears, enter login mmi.
13 When MMI> appears, type in the following command:
set_sc <modem number> <sector number> <channel> <PN offset>
where:
S <modem number> is the modem on MCC–DO card to be tested
S <sector number> is the sector number of the appropriate BBX (according to carrier selected in
LMF)
S <channel> is the appropriate channel (according to carrier selected in LMF) in the hexadecimal
format 0xHHHH or NNNN format (normal decimal).
S <PN offset> is set to 0 (zero)
table continued on next page