User's Manual Part 4

MCC–DO Tests – continued
MAY 2004
A-3
1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU
PRELIMINARY
Table A-1: Procedure to Test MCC–DO Code Domain Power
Step Action
12 To generate a pattern, enter the following command:
fl_pattern 3
13 On the Agilent E4406, set the Code Domain:
S Press Measure button
S Press More button until Code Domain option is displayed
S Select Code Domain
S Press Meas Setup button, then press Meas Interval, enter 3.
S Press Meas Control button, then press Measure to set it to Cont
S Press Meas Control button
S Set Channel Type to MAC
S Press More button until Trig Source option is displayed
S Press Trig Source key and select Ext Rear option
S Press More button until Advanced option is displayed
S Select Advanced option
S If Chip Rate option is set to a value different than 1.228800, select Chip Rate and set it to
1.228800
S Select Active Set Th option to a value calculated using the following formula:
xcvr_gain – cable_loss – 2dB
S Press Display button and set the I/Q Combined Power Bar to On
S Press Display button, press Code Order button, select Hadamard option
S To set appropriate frequency value, press Frequency and enter the value calculated according to the
following formula:
<tx_base_band_value> + 0.05*<chan_no> [MHz]
14 Read the value of the power for each MAC channel.
15 Note the Max Inactive Ch value. The Max Inactive Ch value is –31dB or lower.
A