User's Manual Part 4

MCC–DO Tests – continued
PRELIMINARY
1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU MAY 2004
A-2
Follow the procedure in Table A-1 to test the MCC–DO Code Domain
Power.
Table A-1: Procedure to Test MCC–DO Code Domain Power
Step Action
1 Click the BBX(s) on DO carrier to be tested.
2 On the menu, click the EvDO Tests > TX>Start Manual Tx ATP.
3 Select the appropriate carrier from the Sector/Carrier list.
4 Click the OK button.
A status report window is displayed.
5 Test tesults are displayed in the window.
6 Connect an MMI cable to the MCC–DO card.
7 Open a HyperTerminal application.
8 Open the COM to the MCC–DO MMI. Set parameters as follows:
S Bits per second: 9600
S Data bits: 8
S Parity: None
S Stop bits: 1
S Flow control: None
9 When the login prompt appears, enter login mmi.
10 When MMI> appears, type in the following command:
set_sc <modem number> <sector number> <channel> <PN offset>
where:
S <modem number> is the modem on MCC–DO card to be tested
S <sector number> is the sector number of the appropriate BBX (according to carrier selected in
LMF)
S <channel> is the appropriate channel (according to carrier selected in LMF) in the hexadecimal
format 0xHHHH or NNNN format (normal decimal)
S <PN offset> is set to 0 (zero)
11 Enable the modem on MCC–DO card by entering the following command:
enable <modem number>
where:
S <modem number> is the modem selected in step 10.
table continued on next page
A