User's Manual Part 2

Bay Level Offset Calibration – continued
6-82 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU MAY 2004
PRELIMINARY
Table 6-34: Procedure for Initial Set-up for TX Calibration
n Step Action
1 Delete the existing calibration file (if any) from the BTS folder on LMF laptop from the location
C:\wlmf\cdma\bts–#, where # is the BTS number.
2 To edit the nominal TX BLO, from the Util menu, select Edit > TX Nominal Offset. In the TX
Cal Parameter window, make any necessary changes to ensure the TX BLO Nominal Offset (in
dB) is set to the following:
For 800 MHz, TX Nominal Offset value is 40.0 (dB), and the Allowed error range, plus or
minus (in dB) is 1.5
3 Download the data, which includes BLO values, to all the BBXs. From the Device menu, select Down-
load > Data
TX Calibration
Before installing any test equipment directly to any BTS
TX OUT connector, first verify no CDMA channels are
keyed. Failure to do so can result in serious personal injury
and/or equipment damage.
WARNING
Always wear an approved anti–static wrist strap while
handling any circuit card or module. If this is not done,
there is a high probability that the card or module could be
damaged by ESD.
CAUTION
At new site installations, to facilitate the complete test of
the CCP2 Shelf empty BBX slots may be populated to
ensure that all BBX TX paths are tested.
This procedure can be bypassed on operational sites that
are due for periodic optimization.
Prior to testing, view the CDF (or NECF) file to verify the
correct BBX slots are equipped. Edit the file as required to
include BBX slots not currently equipped (per Systems
Engineering documentation).
NOTE
All Cal/Audit and TX
Calibration Procedure
The LMF All Cal/Audit and TX calibration procedures are essentially
identical, except for the step that selects the type of procedure desired
(Refer to Step 4 in Table 6-35).
6