User's Manual Part 2

Test Set Calibration – continued
6-66 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU MAY 2004
PRELIMINARY
Manual
Agilent E4406A Transmitter Tester The E4406A does not support
the power level zeroing calibration performed by the WinLMF. If this
instrument is to be used for Bay Level Offset calibration and calibration
is attempted with the WinLMF Calibrate Test Equipment function, the
WinLMF will return a status window failure message stating that zeroing
power is not supported by the E4406A. Refer to the Equipment
Calibration section of Appendix B for instructions on using the
instrument’s self–alignment (calibration) function prior to performing
Bay Level Offset calibration.
Power Meters – Manual power meter calibration procedures to be
performed prior to automated calibration are included in the Equipment
Calibration section of Appendix B .
Cable Calibration – Manual cable calibration procedures using the HP
8921A and Advantest R3465 communications system analyzers are
provided in the Manual Cable Calibration section of Appendix B, if
needed.
GPIB Addresses
GPIB addresses can range from 1 through 30. The WinLMF will accept
any address in that range, but the numbers entered in the WinLMF
Options window GPIB address boxes (Table 6-23 and Table 6-24) must
match the addresses set in the test equipment. Motorola recommends
using 1 for a CDMA signal generator, 13 for a power meter, and 18 for a
communications system analyzer. To verify and, if necessary, change the
GPIB addresses of the test equipment, refer to the Setting GPIB
Addresses section of Appendix B.
Selecting Test Equipment
Serial Connection and Network Connection tabs are provided in the
WinLMF Options window to specify the test equipment connection
method. The Serial Connection tab is used when the test equipment
items are connected directly to the WinLMF computer through a GPIB
box (normal setup). The Network Connection tab is used when the test
equipment is to be connected remotely via a network connection or the
Agilent E7495A Communications Test Set is used.
Prerequisites
Be sure the following have been completed before selecting test
equipment:
S Test equipment is correctly connected and turned on.
S GPIB addresses set in the test equipment have been verified as correct
using the applicable procedures in Appendix B.
S WinLMF computer serial port and test equipment are connected to the
GPIB box.
6