MAY 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU 6-65
PRELIMINARY
Background
Proper test equipment calibration helps to ensure accurate BTS
optimization and acceptance testing by assuring that the test equipment
and associated cables do not introduce measurement errors.
If the test equipment set being used to optimize or test the
BTS has been calibrated and maintained as a set, this
procedure does not need to be performed.
NOTE
This procedure must be performed prior to beginning the optimization.
Verify all test equipment (including all associated cables and adapters
actually used to interconnect test equipment items and the BTS) has been
calibrated and maintained as a set.
If any piece of test equipment, test cable, or RF adapter
that makes up the calibrated test equipment set has been
replaced, the set must be re-calibrated. Failure to do so can
introduce measurement errors, resulting in incorrect
measurements and degradation to system performance.
Motorola recommends repeating cable calibration before
testing at each BTS site.
CAUTION
Calibration of the communications system analyzer (or
equivalent test equipment) must be performed at the site
before calibrating the overall test equipment set. Calibrate
the test equipment after it has been allowed to warm–up
and stabilize for a a minimum of 60 minutes.
NOTE
Calibration Procedures
Included
Automatic
Procedures included in this section use the WinLMF automated
calibration routine to determine path losses of the supported
communications analyzer, power meter, associated test cables, adapters,
and (if used) antenna switch that make up the overall calibrated test
equipment set. After calibration, the gain/loss offset values are stored in
a test measurement offset file on the WinLMF computer.