User's Manual Part 2

Test Equipment Setup
MAY 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU 6-51
PRELIMINARY
Connecting Test Equipment to
the BTS
The following types of test equipment are required to perform calibration
and ATP tests:
S WinLMF
S Communications system analyzer model supported by the WinLMF
S Power meter model supported by the WinLMF (required when using
the HP 8921A/600 and Advantest R3465 analyzers)
S Non–radiating transmit line termination load
S Directional coupler and in–line attenuator
S RF cables and adapters
Refer to Table 6-21 for an overview of connections for test equipment
currently supported by the WinLMF. In addition, see the following
figures:
S Figure 6-14, Figure 6-15, and Figure 6-16 show the test set
connections for TX calibration
S Figure 6-17 through Figure 6-20 show the test set connections for
optimization/ATP tests
Test Equipment GPIB Address
Settings
All test equipment is controlled by the WinLMF through an
IEEE–488/GPIB bus. To communicate on the bus, each piece of test
equipment must have a GPIB address set which the WinLMF will
recognize. The standard address settings used by the WinLMF for the
various types of test equipment items are as follows:
S Signal generator address: 1
S Power meter address: 13
S Communications system analyzer: 18
Using the procedures included in the Verifying and Setting GPIB
Addresses section of Appendix B, verify and, if necessary, change the
GPIB address of each piece of employed test equipment to match the
applicable addresses above
.
Supported Test Equipment
CAUTION
To prevent damage to the test equipment in high power
configurations, all transmit (TX) test connections must be
through a 30 dB directional coupler plus a 20 dB in-line
attenuator for the 800 MHz BTSs.
Attenuators are not required for low power configurations.
IS–95A/B Operation
Optimization and ATP testing for IS–95A/B sites or carriers may be
performed using the following test equipment:
6