User's Manual Part 2

CSA System Time – GPS & HSO/MSO Verification – continued
6-44 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU MAY 2004
PRELIMINARY
High Stability Oscillator /
Medium Stability Oscillator
(HSO/MSO)
General
CSA and HSO/MSO
The CSA utilizes timing signals provided by either an HSO or MSO to
maintain BTS synchronization during the absence of valid GPS timing
information. WHen a GPS timing signal is available the CSA is
responsible for calibration of the HSO or MSO clock to maximize the
backup timing interval. A minimum period of 24 hours of operation with
a valid GPS reference is required to fully calibrate the HSO backup
reference such that a 24 hour backup interval may be provided.
HSO
The HSO is a free–running backup oscillator that is capable of providing
a minimum backup interval of 24 hours.
MSO
The MSO is a free–running backup oscillator that is capable of providing
a minimum backup interval of 8 hours.
NOTE
Allow the base site and test equipment to warm up for 60
minutes after any interruption in oscillator power. CSA card
warm-up allows the oscillator oven temperature and oscillator
frequency to stabilize prior to test. Test equipment warm-up
allows the Rubidium standard time base to stabilize in frequency
before any measurements are made.
6