User's Manual Part 2

Using the LMF – continued
6-26 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU MAY 2004
PRELIMINARY
Table 6-7: BTS GUI Login Procedure
n ActionStep
4 Click on the desired BTS number.
5 Click on the Network Login tab (if not already in the forefront).
6 Enter correct IP address (normally 128.0.0.2) for a field BTS, if not correctly displayed in the IP
Address box.
7 Type in the correct IP Port number (normally 9216) if not correctly displayed in the IP Port box.
8 Click on Ping.
If the connection is successful, the Ping Display window shows text similar to the following:
Reply from 128 128.0.0.2: bytes=32 time=3ms TTL=255
If there is no response the following is displayed:
128.0.0.2:9216:Timed out
If the GLI fails to respond, reset and perform the ping process again. If the GLI still fails to
respond, typical problems are shorted BNC to inter–frame cabling, open cables, crossed A and B
link cables, missing 50–Ohm terminators, or the GLI itself.
9 If required, match the device corresponding to the BTS configuration by selecting
Multi-channel Preselector type from the Multi-channel Preselector drop–down list (default is
MPC).
10 Click on Login. (A BTS tab with the BTS and frame numbers is displayed.)
NOTE
S If an attempt is made to log into a BTS that is already logged on, all devices will be gray.
S There may be instances where the BTS initiates a log out due to a system error (i.e., a device
failure).
S If the GLI is OOS–ROM (blue), it must be downloaded with RAM code before other devices
can be seen.
S If the GLI is OOS–RAM (yellow), it must be enabled before other installed devices can be seen.
6