User's Manual Part 2
Span Lines – Interface and Isolation
MAY 2004
1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU
PRELIMINARY
6-16
T1/E1 Span Interface
At active sites, the OMC–R/CBSC must disable the BTS
and place it out–of–service (OOS). DO NOT remove the
span line cable connectors until the OMC–R/CBSC has
disabled the BTS.
NOTE
Before connecting the WinLMF computer to the BTS LAN, the
OMC–R/CBSC must disable the BTS and place it OOS. This will allow
the WinLMF to control the BTS, and prevent the CBSC from
inadvertently sending control information to the BTS during
WinLMF–based tests.
Isolate BTS from T1/E1 Spans
Once the OMC–R/CBSC has disabled the BTS, the spans must be
disabled to ensure the WinLMF will maintain control of the BTS.
T1/E1 Span Isolation
Table 6-5 describes the action required for span isolation.
Table 6-5: T1/E1 Span Isolation
Step Action
1 Have the OMC–R/CBSC operator place the BTS OOS.
2 To disable the span lines, disconnect the span or spans from the CBIO Network Span–1X or Group 1
Span–EVDO sockets.
If in an outdoor configuration, then unlock and open TME left side door to gain access to rear of BTS.
6