User's Manual Part 2
Introduction to Optimization and Calibration
6-4 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU MAY 2004
PRELIMINARY
Overview
This section describes procedures for isolating the BTS from the span
lines, preparing and using the WinLMF, downloading system operating
software, CSA reference verification/optimization, set up and calibration
of the supported test equipment, and transmit/receive paths are
functioning properly.
Before using the WinLMF, use an editor to view the
“CAVEATS” section in the “readme.txt” file in the c:\wlmf
folder for any applicable information.
NOTE
Optimization Process
Summary
After a BTS is physically installed and the preliminary operations, such
as power up, have been completed, the WinLMF is used to optimize the
BTS. The basic optimization process consists of the following:
1. Download GLI3 (GLI–bts#–1) with application code and data and
then enable GLI3.
2. Use the WinLMF status function and verify that all of the installed
devices of the following types respond with status information:
CSA, BBX, GLI3, and MCC. If a device is installed and powered up
but is not responding and is colored gray in the BTS display, the
device is not listed in the CDF file. The CDF/NECF file must be
corrected before the device can be accessed by the WinLMF.
3. Download device application code and data to all devices of the
following types:
– CSA
– BBX–1X
– MCC–1X
4. Verify the operation of the GPS and HSO/MSO signals.
5. Using the WinLMF test equipment selection function, select the test
equipment to be used for the calibration.
6. Calibrate the TX and RX test cables if they have not previously been
calibrated with the WinLMF computer and software build which will
be used for the optimization/calibration. Cable calibration values can
be entered manually, if required.
7. Connect the required test equipment for a full optimization.
8. Select all of the BBXs and all of the MCCs and use the full
optimization function. The full optimization function performs TX
calibration, BLO download, TX audit, all TX tests, and all RX tests
for all selected devices.
9. If the TX calibration fails, repeat the full optimization for any failed
paths.
6