Fan Module
9-4 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU MAY 2004
PRELIMINARY
Introduction
The fan module is located above the CCP2 Shelf at the front of the
Compact BTS.
The fan mdoule is a modular device allowing easy replacement. The
electrical connection for DC power is made through a connector at the
rear of the module. The connector is automatically engaged when the fan
module is inserted and seated.
System Impact/Considerations
At room temperature, the fan module is very quiet.
Operation can be verified by holding a hand over the
exhaust grill on top and feeling for air movement.
NOTE
Performing this replacement procedure will not cause
downtime or interrupt call processing, but it will trigger
alarms.
IMPORTANT
*
If a fan begins to degrade or fails, an alarm signal will be sent to the
Clock Synchronization Alarms card in the CCP2 Shelf.
Required Items
Documents
None.
Tools
None.
Replacement Units
For –48 VDC – One fan module (STLN4696)
For +27 VDC – One fan module (STLN6210)
Prerequisite
Coordinate this repair task with the OMC–R operator.
IMPORTANT
*
Contact the OMC–R operator before performing the replacement
procedure. Tell the operator that the fan module will be replaced and that
alarms can be expected.
9