Prepare to Leave the Site – continued
8-4 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU MAY 2004
PRELIMINARY
Table 8-4: Bring Modules into Service
Step Action
4 Click Cancel to close the transceiver parameters window, if applicable.
5 Click OK to close the status report window.
– The color of devices which successfully change to INS will change bright green.
WinLMF Removal
Perform the procedure in Table 8-5 as required to terminate the WinLMF
GUI session and remove the WinLMF computer.
Table 8-5: Terminate the WinLMF Session and Remove the WinLMF
Step Action
1
! CAUTION
Do not power down the WinLMF terminal without performing the procedure below. Corrupted/lost
data files may result.
Log out of all BTS sessions and exit WinLMF by clicking on File in the WinLMF window menu bar and
selecting Logout and Exit from the pull–down list.
2 In the Windows Task Bar, click Start and select Shutdown. Click Ye s when the Shut Down Windows
message appears.
3 Wait for the system to shut down and the screen to go blank.
4 Disconnect the WinLMF terminal Ethernet port from the BTS frame.
5 Disconnect the WinLMF terminal serial port, the RS–232–to–GPIB interface box, and the GPIB
cables as required for equipment transport.
Connecting BTS T1/E1 Spans
Perform the procedure in Table 8-6 to connect any T1 or E1 span
connectors removed previously to allow the WinLMF to control the
BTS.
Table 8-6: Connect T1 or E1 Spans
Step Action
1 Re–connect any disconnected span lines.
2 Verify span status, ensuring the OMC–R/CBSC can communicate with the BTS.
8