User's Manual Part 2
TX Code Domain Power/Noise Floor Acceptance Test – continued
MAY 2004
7-19
1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU
PRELIMINARY
Table 7-8: Test Code Domain Power/Noise Floor
Step Action
1 Set up the test equipment for TX acceptance tests per Table 7-1.
2 Select the BBXs and MCCs to be tested.
3 Click on Tests in the BTS menu bar, and select TX > Code Domain Power... from the pull–down
menus.
4
Select the appropriate carrier(s) and sector(s) (carrier-bts#-sector#-carrier#) from those displayed in the
Channels/Carrier pick list.
NOTE
To select multiple items, hold down the Shift or Ctrl key while clicking on pick list items to select
multiple carrier(s)–sector(s).
5
Verify that the correct channel number for the selected carrier is shown in the Carrier # Channels
box.
– If it is not, obtain the latest bts–#.cdf and cbsc–#.cdf files from the CBSC.
NOTE
If necessary, the correct channel number may be manually entered into the Carrier # Channels box.
6 Click OK to display a status bar followed by a Directions pop-up window.
7 Follow the cable connection directions as they are displayed, and click the Continue button to begin
testing.
– As the ATP process is completed, results will be displayed in a status report window.
8 Click the Save Results or Dismiss button.
NOTE
If Dismiss is used, the test results will not be saved in the test report file.
7