PRELIMINARY
Figure 2-7: Indoor Functional Clearances for BTS Side–By–Side Configuration
Rear Clearance
50 mm minimum
Top View
Side View
Side Clearance
50 mm minimum
NOTE:
For access to RF filter tray
remove BTS from the shelf.
Seated side–by–side on the
mounting plate does not interfere
with BTS ventilation.
Front View
Front Clearance
50 mm minimum
Side Clearance
50 mm minimum
625 mm minimum
clearance
250 mm minimum
clearance
NOTE:
The 100 mm (4 in.) clearance above
the cCLPA only applies if there is a
single cCLPA present.
If two cCLPAs are used, the clearance
between the cCLPAs is 625 mm (25 in. )
minimum.
NOTE:
Normal clearance for cCLPA above
BTS is 125 mm (5 in.) minimum.
If two BTSs are used, the clearance
is 250 mm (10 in.) minimum.
Top Clearance
100 mm minimum