User's Manual Part 1

Power Distribution Enclosure Installation – continued
MAY 2004
4-37
1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU
PRELIMINARY
Mounting Bracket Assembly
Procedure
Pole Mount
Follow the procedure in Table 4-19 to install the pole mounting bracket
assembly and wall mounting bracket for pole mounting the PDE.
Once PDE is installed, DO NOT use it as a step ladder. It
will not support a person standing on top or hanging from
it.
WARNING
Table 4-19: Procedure to Install Mounting Bracket Assembly on a Pole
Step Action
1 Wrap the mounting bracket straps around the pole to gauge the proper length.
2 Cut straps to proper length.
3 Slide straps through slots in mounting bracket assembly.
4 Secure mounting bracket to pole using the straps.
5 Secure Wall Mounting Bracket to Pole Mounting Bracket Assembly using 8 M6 bolts. Torque bolts to
3.4 N–M (30 in–lbs).
n WARNING
The PDE weighs 15 kg (30 lbs). One person can mount the PDE. It is recommended that a minimum
of two people or one person using a mechanical lift mount the PDE.
Remove the Heat Exchanger prior to mounting the PDE.
NOTE
Initial height is determined by customer. Minimum height from the ground is 1 meter.
6 Hang PDE on Wall Mounting Bracket and secure using 4 M6 screws. Torque screws to 3.4 N–M (30
in–lbs).
Wall Mount
Follow the procedure in Table 4-20 to install the Wall Mounting Bracket
on a wall for the PDE.
Once PDE is installed, DO NOT use it as a step ladder. It
will not support a person standing on top or hanging from
it.
WARNING
4