cCLPA Grounding
Cable Description
Since the length of this cable varies from site to site, no specific length is
assigned. Table 4-6 lists the components required to build a ground
cable.
Table 4-6: Ground Cable and Lug Description and Part Number
Cable Qty. Part Number Description
A 1 Customer
Supplied
Ground cable, 6 -AWG, insulated copper wire.
1 Customer
Supplied
Two Hole, Long Barrel lug connector, 6 AWG, 1/4–inch diameter,
5/8–inch stud hole spacing, 13/32 Tang width.
Figure 4-8: cCLPA Mounting to Rack
Rack
Screws
Screws
Mounting Hole
Location for
cCLPA
Screw for
Mounting
cCLPA
Screw for
Mounting
cCLPA