Instruction Manual

Isolate Span Lines/Connect LMF
DRAFT
SC4812ET BTS Optimization/ATP CDMA LMF
Apr 2001
3-4
Isolate BTS from T1/E1 Spans
At active sites, the OMC/CBSC must disable the
BTS and place it out of service (OOS). DO NOT
remove the span surge protectors until the
OMC/CBSC has disabled the BTS.
IMPORTANT
*
Each frame is equipped with one 50pair punch block for spans,
customer alarms, remote GPS, and power cabinet alarms. See Figure 3-2
and refer to Table 3-1 for the physical location and pin callout
information. To disable the span, pull the surge protectors for the
respective span.
Before connecting the LMF to the frame LAN, the OMC/CBSC must
disable the BTS and place it OOS to allow the LMF to control the
CDMA BTS. This prevents the CBSC from inadvertently sending
control information to the CDMA BTS during LMF based tests.
Configure Channel Service
Unit
The MPATH 537 Channel Service Unit (CSU) provides inband
SNMPmanaged digital service access to T1 and fractional T1 lines.
MPATH units plug into the ADC Kentrox 2slot frame (see
Figure 3-1).
Remote MPATH management is available via SNMP over an inband
data link on the T1 line (using a facility data link or 864 Kbps of a DS0
channel). The unit at the near end of the management path can be an
SNMP manager or another MPATH CSU.
Each 19 inch rack can support two CSU MPATH 537 modules. Each
MPATH 537 module supports one and only one span connection.
Programming of the MPATH is accomplished through the DCE 9pin
connector on the front panel of the CSU shelf. Manuals and a Microsoft
Windows programming disk is supplied with each unit.