Instruction Manual

Module Front Panel LED Indicators and Connectors continued
Apr 2001
6-27
SC4812ET BTS Optimization/ATP CDMA LMF
DRAFT
PWR/ALM LED
LENS
(REMOVABLE)
ACTIVE LED
PWR/ALM ACTIVE
Figure 6-3: MCC24/8E Front Panel LEDs and LED Indicators
PWR/ALM
OFF - operating normally
ON - briefly during powerĆup and during failure
ąconditions
ACTIVE
LED OPERATING STATUS
RAPIDLY BLINKING - Card is codeĆloaded but
ąnot enabled
SLOW BLINKING - Card is not codeĆloaded
ON - card is codeĆloaded and enabled
ą(INS_ACTIVE)
COLOR
GREEN
RED
RED
ON - fault condition
SLOW FLASHING (alternating with green) - CHI
ąbus inactive on powerĆup
An alarm is generated in the event of a failure
FW00224
LPA Shelf LED Status
Combinations
LPA Module LED
Each LPA module contains a bicolor LED just above the MMI
connector on the ETIB module. Interpret this LED as follows:
GREEN LPA module is active and is reporting no alarms (Normal
condition).
Flashing GREEN/RED LPA module is active but is reporting an
low input power condition. If no BBX is keyed, this is normal and
does not constitute a failure.
Flashing RED LPA is in alarm.
6