Troubleshooting: Transmit ATP
68P64115A18–1
Mar 2003
1X SC 4812T Lite BTS Optimization/ATP Software Release R2.16.1.x
DRAFT
6-16
Cannot Perform Code Domain Power and Noise Floor Measurement
Table 6-16: Troubleshooting Code Domain Power and Noise Floor Measurement Failure
n Step Action
1 Verify presence of RF signal by switching to spectrum analyzer screen on the communications
system analyzer.
2 Verify PN offset displayed on analyzer is same as PN offset being used in the CDF file.
3 Disable and re-enable MCC (one or more MCCs based on extent of failure).