User's Manual

Table Of Contents
Expansion Frame Inter-Frame Cabling
68P64115A194
Mar 2003
1X SC 4812T-MC BTS Hardware Installation - Software Release R2.16.1.x
CONTROLLED INTRODUCTION
3-7
Expansion Frame Inter-Frame Cabling
This section describes the connections between an expansion frame with
a starter frame.
Remote GPS Distribution (RGD) Board Diagram
Figure 3-5 shows the RGD board cable connections. Both RGD and Site
I/O boards are on the strater BTS. Table 3-1 provides a description of all
cables associated with the installation of RGD.
Figure 3-5: RGD Board Cable Connections
NOTE:
RGD card is required on the Starter frame only.
It provides Remote GPS signal to the Expansion frame.
RGD
To Expansion Frame
Not used
(Main out)
Remote GPS Antenna
Not used
Surge Protected
Punch block
Site I/O
ti-CDMA-WP-00087-v01-ildoc-ftw–REF
A1
A2
B
C
NOTE
S Cables A1 and A2 must be punched into the punch block as
if they were part of the same cable, cut in the middle. The
same colors must be punched on both sides of the punch
block.
S Frame MUST be equipped with CSM2 for Remote GPS
operations.
S Remote GPS is NOT supported in all Motorola 4-digit
frames.
3