BTS 60 Degree Sector (6 Sector) Transmit Path Cabling
68P64115A194
Mar 2003
1X SC 4812T-MC BTS Hardware Installation - Software Release R2.16.1.x
CONTROLLED INTRODUCTION
2-31
60 Degree Sector Configuration
Table 2-20 provides the Cable Run List for 60 degree sector transmit
paths.
Table 2-20: Cable Run List for 60 Degree Sector TX Configuration
Cable Cable Parts Connecting Lightning Arrestors To BTS TX Connectors
G Direct
Quantity 6
TX Ports for 6 Sector Configuration
Table 2-21: Cable Run List for 60 Degree Sector Receive Path Cabling
Cable Cable path connecting Lightning Arrestors to BTS TX connectors TX Ports Used
Quantity 6 TX 1A–6A
Procedure
Install each cable by using the cable run list in Table 2-20, the cabling
diagram in Figure 2-12, and the procedure in Table 2-22. Each cable is
installed the same way.
Table 2-22: Installing the 60 Degree Sector TX Path Cables
Step Action
1 Attach the connector–equipped end of the cables to the BTS TX connectors.
2 Route the cables to the lightning arrestors.
3 Cut the cables to length and label them accordingly. Install connectors on the cables and attach the
cables to the Lightning Arrestors.