BTS 60 Degree Sector (6 Sector) Transmit Path Cabling
68P64115A194
Mar 2003
1X SC 4812T-MC BTS Hardware Installation - Software Release R2.16.1.x
CONTROLLED INTRODUCTION
2-29
BTS 60 Degree Sector (6 Sector) Transmit Path Cabling
Objective
The objective of this procedure is to install the BTS transmit path
cabling.
Cable Labels
The cable designations referenced in Table 2-20, provide the quantities
and descriptions of the cables required for the procedure.
Cabling Diagram
Figure 2-12 and Figure 2-13 shows direct connect cable configurations
(both inside and outside the BTS frame). Table 2-21 describes the
antenna cable connection ports.
Figure 2-12: 60 Degree Sector (6 Sector) Transmit Path Cabling Details (Outside Frame)
TX OUT
LIGHTNING
ARRESTOR
ANTENNA
CARRIER 1 & 2
G (See Table 2-20)
I/O PLATE
6
1
.
.
6
1
.
.
6
ti-CDMA-WP-00048-v04-ildoc-ftw–REF
123
456
789
10 11 12
DIRECT CONNECT
2