User's Manual

Table Of Contents
Alarm / Span Cabling
68P64115A194
Mar 2003
1X SC 4812T-MC BTS Hardware Installation - Software Release R2.16.1.x
CONTROLLED INTRODUCTION
2-10
Alarm / Span Cabling
Objective
The objective of this procedure is to install the BTS alarm and span line
cabling.
Cable Labels
The cable designations are referenced to Table 2-1 in the “Overall
Cabling Diagrams and Description” area.
Equipment Needed
Table 2-2 lists the quantity and description of the required cables.
Table 2-2: Cables Needed for Alarm and Span Line Cabling
Cable Qty. Part Number Description
A 1 or 2 CGDS1583461 Cable, 50-wire, shielded twisted 25 pair, 100 ohm, 24-AWG, 7.6 m
(25 ft), one male TELCO connector attached. One end of cable has
shielded twisted pairs, no connector.
CGDS1583462 Cable, 50-wire, shielded twisted 25 pair, 10 ohm, 24-AWG, 15.2 m
(50 ft), one male TELCO connector attached. One end of cable has
shielded twisted pairs, no connector.
B 2 CGDS1583451 Cable, 60-wire, 100 ohm, 24 AWG, 7.6 m (25 ft), one 60-pin
connector. One end of cable has shielded twisted pairs.
CGDS1583452 Cable, 60-wire, 100 ohm, 24 AWG, 15.2 m (50 ft), one 60-pin
connector. One end of cable has shielded twisted pairs.