Objective
The objective of this procedure is to install the 120 degree BTS transmit
path cabling.
Cable Labels
The cable designations are referenced to Table 2-1 in the “Cabling
Diagrams and Description” area. Table 4-7 and Table 4-8 provide the
quantities and descriptions of the cables required for this procedure.
Cabling Diagram
Figure 4-7 shows two types of configurations; select the diagram that
depicts your site’s configuration. Table 4-7 and Table 4-8, on page 4-13,
describes the antenna cable connection ports.
Figure 4-7: 120 Degree Sector (3 Sector) Transmit Path Cabling Details
LIGHTNING
ARRESTOR
ANTENNA
NOTE: Unused TX ports on the DDC must be terminated with 50
ohm loads (Part #58–82106P01) which are included with
the duplexer mounting hardware kit (STLN4001A).
WITH OPTIONAL DIRECTIONAL COUPLER
WITH OPTIONAL DUPLEXER DIRECTIONAL COUPLER
DIRECTIONAL
COUPLER
G
G
G
LIGHTNING
ARRESTOR
ANTENNA
G
G
G
DDCDDC
ti-CDMA-WP-00050-v04-ildoc-ftw
TX OUT
123
456
789
10 11 12
RX
I/O PLATE
CARRIER 1–4
Table 4-7: Cables Needed for 120 Degree Sector Transmit Path
Cable Qty. Part Number Description
G (see Table 4-8) CGDS2212602 15 ft Jumper Cable, N/M–N/M.