1X SC 4812T Lite BTS Optimization/ATP Software Release R2.16.1.x
DRAFT
1-20
Internal Assemblies and FRUs
The BTS frame houses the fan modules, Small CDMA Channel
Processor (SCCP) shelf, RF Power Amplifier modules, PA trunking
modules, 2:1 combiners.
RF filtering includes: DRF – Duplexers with TX Filter, RX Filter, and
Diversity RX Filter and TRF – Non-Duplexed TX Filter, RX Filter, and
Diversity RX Filter.
Power system components include an AC Power Input/Filter, DC Filters,
+27 Vdc Power Distribution Assembly (PDA).
Figure 1-2 and Figure 1-3 show the location of the internal assemblies
and Field Replaceable Units (FRU). A brief description of each item is
found in the following paragraphs.
Figure 1-3: I/O Interconnect Plate
FRONT
SITE I/O
LAN
CONNECTIONS
GPS IN
HSO/LFR
RF FILTERING
POWER INPUT/
DC FILTER
ETHERNET ROUTER (IF USED;
OTHERWISE, FILLER PLATE)
EXP FILLER
PLATE
REAR
SPAN I/O
ti-CDMA-WP-00214-v01-ildoc-ftw
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ÄÄÄÄÄÄÄÄÄÄ
ALARM
CONNECTORS
POWER INPUT/
AC FILTER
FILLER PLATE
DC Power Distribution Assembly (PDA)
Both rectifier output voltage and back–up battery voltage are routed to
the PDA (Figure 1-3) where they are combined into system DC bus
voltage. The PDA provides distribution of DC power and system DC
bus protection from the loads with MAIN BREAKER and the smaller
post–distribution circuit breakers. MAIN BREAKER permits removal of
all frame loading from the bus. The 13 post–distribution circuit breakers
permit removal of individual loads.