User's Manual

Table Of Contents
Test Equipment Set-up68P64115A18–1
Mar 2003
1X SC 4812T Lite BTS Optimization/ATP Software Release R2.16.1.x
DRAFT
3-55
Test Equipment Set-up
Connecting Test Equipment to the BTS
The following types of test equipment are required to perform calibration
and ATP tests:
S LMF
S Communications system analyzer model supported by the LMF
S Power meter model supported by the LMF (required when using the
HP 8921A/600 and Advantest R3465 analyzers)
S Non–radiating transmit line termination load
S Directional coupler and in–line attenuator
S RF cables and adapters
Refer to Table 3-21 for an overview of connections for test equipment
currently supported by the LMF. In addition, see the following figures:
S Figure 3-14, Figure 3-15, and Figure 3-16 show the test set
connections for TX calibration
S Figure 3-17 through Figure 3-22 show the test set connections for
optimization/ATP tests
Test Equipment GPIB Address Settings
All test equipment is controlled by the LMF through an IEEE–488/GPIB
bus. To communicate on the bus, each piece of test equipment must have
a GPIB address set which the LMF will recognize. The standard address
settings used by the LMF for the various types of test equipment items
are as follows:
S Signal generator address: 1
S Power meter address: 13
S Communications system analyzer: 18
Using the procedures included in the Verifying and Setting GPIB
Addresses section of Appendix F, verify and, if necessary, change the
GPIB address of each piece of employed test equipment to match the
applicable addresses above
.