User's Manual

Troubleshooting: Calibration
68P64115A18–1
Mar 2003
1X SC 4812T Lite BTS Optimization/ATP Software Release R2.16.1.x
DRAFT
6-10
Troubleshooting: Calibration
Bay Level Offset Calibration Failure
Table 6-11: Troubleshooting BLO Calibration Failure
n Step Action
1 Verify the power meter or communications system analyzer is configured correctly (see the Test
Equipment Set–up section of Chapter 3), and is connected to the proper BTS TX antenna
connector.
2 If a power meter is being used:
2a Re-calibrate the Power Meter and verify it is calibrated correctly with cal factors from the
power sensor (refer to Appendix F).
2b Verify the power sensor is functioning properly by checking it with the 1–mW (0 dBm) Power
Ref signal.
2c Verify communication between the LMF and Power Meter is working by checking that the
meter display is showing RES :
3 Verify the parameters in the bts–#.cdf file are set correctly for the BTS operating band as
follows:
For 1900 MHz:
Bandclass=1; Freq_Band=16
For 800 MHz:
Bandclass=0; Freq_Band=8
4 Verify that no LPA on the carrier is in alarm state (rapidly flashing red LED).
4a If any are, reset the LPA(s) by pulling the applicable circuit breaker on the DC PDA, and,
after 5 seconds, pushing back in.
5 Verify GPIB adapter is not locked up. Under normal conditions, only 2 green LEDs must be ‘ON’
(Power and Ready). If any other LED is continuously ‘ON’, power-cycle (turn power off and on)
the GPIB Box and retry.