User's Manual

Test Equipment Inter–unit Connection, Testing, and Control
68P64115A18–1
Mar 2003
1X SC 4812T Lite BTS Optimization/ATP Software Release R2.16.1.x
DRAFT
F-24
Advantest R3267/R3562 Test Equipment Interconnection
To provide proper operation during testing when both units are required,
the R3257 spectrum analyzer must be interconnected with the R3562
signal generator as follows:
10 MHz reference signal – Connect a BNC (M)–BNC (M) cable
between the R3562 SYNTHE REF IN connector and the R3267 10
MHz OUT connector as shown in Figure F-17.
Serial I/O – Using the Advantest cable provided, connect the R3267
SERIAL I/O connector to the R3562 SERIAL I/O connector as shown
in Figure F-17.
Figure F-17: Advantest 10 MHz Reference and Serial I/O Connections
TDME0010–1
R3562
SYNTHE REF IN
TO GPIB
BOX
R3562
SERIAL I/O
TO GPIB BOX
R3267
10 MHZ OUT
R3267
SERIAL I/O
F