User Manual
Test Equipment68P09255A57-2
Aug 2002
SC4812ET Optimization/ATP Manual Software Release R16.1.x.x
PRELIMINARY
1-9
Test Cable Calibration
Equipment test cables are very important in optimization. Motorola
recommends that the cable calibration be run at every BTS with the test
cables attached. This method compensates for test cable insertion loss
within the test equipment itself. No other allowance for test cable
insertion loss needs to be made during the performance of tests.
Another method is to account for the loss by entering it into the LMF
during the optimization procedure. This method requires accurate test
cable characterization in a shop. The cable should be tagged with the
characterization information prior to field optimization.
Equipment Warm-up
After arriving at the a site, the test equipment should be plugged in and
turned on to allow warm up and stabilization to occur for as long as
possible. The following pieces of test equipment must be warmed-up for
a minimum of 60 minutes prior to using for BTS optimization or RFDS
calibration procedures.
Communications test set
Rubidium time base
Power meter
Test Equipment List
The following pieces of test equipment are required during the
optimization procedure. Common assorted tools like screwdrivers and
frame keys are not listed but are still required. Read the owner’s manual
on all of the following major pieces of test equipment to understand their
individual operation prior to use in optimization.
NOTE
Always refer to specific OEM test equipment documentation for
detailed operating instructions.
10BaseT/10Base2 Converter
Ethernet LAN transceiver (part of CGDSLMFCPQ1700)
PCMCIA Ethernet Adpater + Ethernet UTP adapter: 3COM model -
Etherlink III 3C589B
Transition Engineering model E-CX-TBT-03 10BaseT/10Base2
converter
NOTE
Xircom model PE3-10B2 or equivalent can also be used to
interface the LMF Ethernet connection to the frame.
RS-232 to GPIB Interface
National Instruments GPIB-232-CT with Motorola CGDSEDN04X
RS232 serial null modem cable (see Figure 1-1) or equivalent; used to
interface the LMF to the test equipment.
Standard RS-232 cable can be used with the following modifications:
1