User Manual
Optimization Overview – continued
Jan 2002
1-9
SC4812ET BTS Optimization/ATP — CDMA LMF
Power Meter
One of the following power meters is required for TX calibration and
audit if an HP8921A or Advantest R3465 analyzer is used:
Hewlett Packard Model HP HP437B with HP8481A power sensor
Gigatronix model 8541C with model 80601A power sensor
Timing Reference Cables
Two BNC–male to BNC–male RG316 cables; 3 meters (10 ft.) long,
used to interconnect the HP8921A/600 or Advantest R3465
communications analyzer to the CSM front panel timing references in
the BTS.
Two Huber & Suhner 16MCX/11BNC/K02252D or
equivalent; right angle MCX–male to standard BNC–male
RG316 cables; 3m long are required to interconnect the
HP8921A/600 communications analyzer to SGLN4132A
and SGLN1145A CSM board timing references.
NOTE
BNC “T” adapter with 50 ohm termination.
This BNC “T” adapter (with 50 ohm termination) is
required to connect between the HP 8921A/600 (or
Advantest R3465) EVEN SECOND/SYNC IN and the
BNC cable. The BNC cable leads to the 2–second clock
connection on the TIB. Erroneous test results may occur if
the “T” adapter with the 50 ohm termination is not
connected.
NOTE
Digital Multimeter
Fluke model 8062A with Y8134 test lead kit or equivalent; used for
precision DC and AC measurements, requiring 4–1/2 digits.
Directional Coupler
Narda model 30661 30 dB (Motorola part no. 58D09732W01) coupler
terminated with two Narda Model 375BN–M loads, or equivalent.
RF Attenuators
20 dB fixed attenuators, 20 W (Narda 768–20); used with test cable
calibrations or during general troubleshooting procedures.
Narda Model 30445 30 dB (Motorola Part No. 58D09643T01) coupler
terminated with two Narda Model 375BN–M loads, or equivalent.
1