Power Delta Calibration – continued
Jan 2002
G-11
SC4812ET BTS Optimization/ATP — CDMA LMF
Table G-4: Agilent E4406A Power Delta Calibration Procedure
Step Action
12
Calculate the Power Calibration Delta value. The delta value is the power meter measurement minus
the Agilent measurement.
Delta = A – B
Example: Delta = –0.70 dBm – (–1.25 dBm) = 0.55 dBm
Example: Delta = 0.26 dBm – 0.55 dBm = –0.29 dBm
These examples are included to show the mathematics and do not represent actual readings.
NOTE
Add this delta value to the TX Cable Loss value during In–Service Calibration.
Figure G-7: Delta Calibration Setup – Agilent E4432B to HP437