User Manual

Test Equipment Preparation
Jan 2002
F-1
SC4812ET BTS Optimization/ATP CDMA LMF
Purpose
This appendix provides information on setting up the HP8921 with PCS
interface, the HP8935 and the Advantest R3465. The Cybertest test set
doesnt require any setup.
HP8921A Test Equipment
Connections
Table F-1 depicts the rear panels of the HP 8921A test equipment as
configured to perform automatic tests. All test equipment is controlled
by the LMF via an IEEE488/GPIB bus. The LMF expects each piece
of test equipment to have a factory-set GPIB address (refer to Table F-4).
If there is a communications problem between the LMF and any piece
of test equipment, you should verify that the GPIB addresses have been
set correctly and that the GPIB cables are firmly connected to the test
equipment.
Figure F-1 shows the connections when not using an external 10 MHz
Rubidium reference.
Table F-1: HP8921A/600 Communications Test Set Rear Panel Connections Without Rubidium
From Test Set: To Interface:
8921A 83203B CDMA 83236A PCS
Connector Type
CW RF OUT CW RF IN SMCfemale SMCfemale
114.3 MHZ IF OUT 114.3 MHZ IF IN SMCfemale SMCfemale
IQ RF IN IQ RF OUT SMCfemale SMCfemale
DET OUT AUX DSP IN SMCfemale SMCfemale
CONTROL I/O CONTROL I/O 45pin custom BUS
10 MHZ OUT SYNTH REF IN BNCmale BNCmale
HPIB INTERFACE HPIB INTERFACE HPIB cable
10 MHZ OUT REF IN BNCmale BNCmale
F