Troubleshooting: Calibration
SC4812ET BTS Optimization/ATP CDMA LMF
Jan 2002
6-6
Bay Level Offset Calibration
Failure
Follow the procedure in Table 6-8 to troubleshoot a BLO calibration
failure.
Table 6-8: Troubleshooting BLO Calibration Failure
Step Action
1 Verify the Power Meter is configured correctly (see the test equipment setup section) and
connection is made to the proper TX port.
2 Verify the parameters in the bts#.cdf file are set correctly for the following bands:
For 1900 MHz:
BandClass=1; FreqBand=16
For 800 MHz:
BandClass=0; FreqBand=8
3 Verify that no LPA in the sector is in alarm state (flashing red LED). Reset the LPA by pulling
the circuit breaker, and after 5 seconds, pushing back in.
4 Re-calibrate the Power Meter and verify it is calibrated correctly with cal factors from sensor
head.
5 Verify GPIB adapter is not locked up. Under normal conditions, only 2 green LEDs must be
ON (Power and Ready). If any other LED is continuously ON, power-cycle (turn power off
and on) the GPIB Box and retry.
6 Verify sensor head is functioning properly by checking it with the 1 mW (0 dBm) Power Ref
signal.
7 If communication between the LMF and Power Meter is operational, the Meter display will
show RES :’’
8 Verify the combiner frequency is the same as the test freq/chan.