User Manual

Troubleshooting: Download continued
Jan 2002
6-5
SC4812ET BTS Optimization/ATP CDMA LMF
Cannot ENABLE Device
Before a device can be enabled (placed in-service), it must be in the
OOS_RAM state (yellow on the LMF) with data downloaded to the
device. The color of the device on the LMF changes to green, once it is
enabled.
The three states that devices can be displayed:
Enabled (green, INS)
Disabled (yellow, OOS_RAM)
Reset (blue, OOS_ROM)
Follow the procedure in Table 6-6 to troubleshoot device enable failure.
Table 6-6: Troubleshooting Device Enable (INS) Failure
Step Action
1 Re-seat card and repeat code and data load procedure.
2 If CSM cannot be enabled, verify the CDF file has correct latitude and longitude data for cell
site location and GPS sync.
3 Ensure primary CSM is in INS_ACT state.
NOTE
MCCs will not go INS without the CSM being INS.
4 Verify 19.6608 MHz CSM clock; MCCs will not go INS otherwise.
5 The BBX should not be enabled for ATP tests.
6 If MCCs give invalid or no system time, verify the CSM is enabled.
LPA Errors
Follow the procedure in Table 6-7 to troubleshoot any LPA errors.
Table 6-7: LPA Errors
Step Action
1 If LPAs continue to give alarms, even after cycling power at the circuit breakers, then connect an
MMI cable to the LPA and set up a Hyperterminal connection. Enter
ALARMS in the
Hyperterminal window. The resulting LMF display may provide an indication of the problem.
(Call Field Support for further assistance.)