User Manual

Troubleshooting68P09255A57-2
Aug 2002
SC4812ET Optimization/ATP Manual Software Release R16.1.x.x
PRELIMINARY
6-9
Checksum Failure
The CSM could have corrupted data in its firmware resulting in a
non-executable code. The problem is usually caused by either electrical
disturbance, or interruption of data during a download. Attempt another
download with no interruptions in the data transfer. Return CSM board
back to repair center if the attempt to reload fails.
GPS Bad RX Message Type
This is believed to be caused by a later version of CSM software (3.5 or
higher) being downloaded, via LMF, followed by an earlier version of
CSM software (3.4 or lower), being downloaded from the CBSC.
Download again with CSM software code 3.5 or higher. Return CSM
board back to repair center if attempt to reload fails.
CSM Reference Source Configuration Error
This is caused by incorrect reference source configuration performed in
the field by software download. CSM kit SGLN1145 and SGLN4132
must have proper reference sources configured (as shown below) to
function correctly.
CSM Kit No.
Hardware Configuration CSM Slot No. Reference Source Configuration
SGLN1145 With GPS Receiver 1 Primary = Local GPS
Backup = Either LFR or HSO
SGLN4132ED
or later
Without GPS Receiver 2 Primary = Remote GPS
Backup = Either LFR or HSO
Takes Too Long for CSM to Come INS
This may be caused by a delay in GPS acquisition. Check the accuracy
flag status and/or current position. Refer to the GSM system time/GPS
and LFR/HSO verification section in Chapter 3. At least 1 satellite
should be visible and tracked for the surveyed mode and 4 satellites
should be visible and tracked for the estimated mode. Also, verify
correct base site position data used in surveyed mode.
6