Table 6-8: Troubleshooting BLO Calibration Failure
ActionStep
7 If communication between the LMF and Power Meter is operational, the Meter display will
show RES :’’
8 Verify the combiner frequency is the same as the test freq/chan.
Calibration Audit Failure
Follow the procedure in Table 6-9 to troubleshoot a calibration audit
failure.
Table 6-9: Troubleshooting Calibration Audit Failure
Step Action
1 Verify Power Meter is configured correctly (refer to the test equipment setup section of chapter
3).
2 Re-calibrate the Power Meter and verify it is calibrated correctly with cal factors from sensor
head.
3 Verify that no LPA is in alarm state (rapidly flashing red LED). Reset the LPA by pulling the
circuit breaker, and, after 5 seconds, pushing back in.
4 Verify that no sensor head is functioning properly by checking it with the 1 mW (0 dBm) Power
Ref signal.
5 After calibration, the BLO data must be re-loaded to the BBX2s before auditing. Click on the
BBX(s) and select Device>Download BLO
Re-try the audit.
6 Verify GPIB adapter is not locked up. Under normal conditions, only 2 green LEDs must be
ON (Power and Ready). If any other LED is continuously ON, power-cycle (turn power off
and on) the GP-IB Box and retry.
Forward link problem
If the BTS passes the reduced ATP tests but has a forward link problem
during normal operation follow the procedure in Table 6-10 to
troubleshoot.
Table 6-10: Troubleshooting Forward Link Failure (BTS Passed Reduced ATP)
Step Action
1 Perform these additional TX tests to troubleshoot a forward link problem:
- TX mask
- TX rho
- TX code domain
6