Table 6-25: No DC Input Voltage to any C-CCP Shelf Module
Step Action
1 Inspect all Harting Cable connectors and back-plane connectors for damage in all the affected
board slots.
2 Perform steps outlined in the RF path troubleshooting flowchart in this manual.
RFDS
The RFDS is used to perform Pre-Calibration Verification and
Post-Calibration Audits which limit-check the RFDS-generate and
reported receive levels of every path from the RFDS through the
directional coupler coupled paths. In the event of test failure, refer to the
following tables.
All tests fail
Follow the procedure in Table 6-26 for problems with RFDS.
Table 6-26: RFDS Fault Isolation - All tests fail
Step Action
1 Check the calibration equipment for proper operation by manually setting the signal generator output
attenuator to the lowest output power setting and connecting the output port to the spectrum analyzer
rf input port.
2 Set the signal generator output attenuator to -90 dBm, and switch on the rf output. Verify that the
spectrum analyzer can receive the signal, indicate the correct signal strength, (accounting for the cable
insertion loss), and the approximate frequency.
3 Visually inspect RF cabling. Make sure each directional coupler forward and reflected port connects to
the RFDS antenna select unit on the RFDS.
4 Check the wiring against the site documentation wiring diagram or the BTS Site Installation manual.
5 Verify RGLI and TSU have been downloaded.
6 Check to see that all RFDS boards show green on the front panel indicators. Visually check (both
board and backplane) for damage.
7 Replace any boards that do not show green with known good boards one at a time in the following
order. Re-test after each is replaced.
- RFDS ASU board.
- RFDS Transceiver board.