User Manual
Using CDMA LMF – continued
Jan 2002
3-37
SC4812ET BTS Optimization/ATP — CDMA LMF
Establishing an MMI
Communication Session
For those procedures that require MMI communications between the
LMF and BTS FRUs, follow the procedure in Table 3-18 to initiate the
communication session.
Table 3-18: Establishing MMI Communications
Step Action
1 Connect the LMF computer to the equipment as detailed in the applicable procedure that requires
MMI communication session.
2 Start the named HyperTerminal connection for MMI sessions by double clicking on its Windows
desktop shortcut.
NOTE
If a Windows desktop shortcut was not created for the MMI connection, access the connection from
the Windows Start menu by selecting:
Programs>Accessories>Hyperterminal>HyperTerminal><Named HyperTerminal Connection
(e.g., MMI Session).
3 Once the connection window opens, establish MMI communication with the BTS FRU by pressing
the LMF computer Enter key until the prompt identified in the applicable procedure is obtained.
NULL MODEM
BOARD
(TRN9666A)
8–PIN TO 10–PIN
RS–232 CABLE (P/N
30–09786R01)
RS–232 CABLE
8–PIN
CDMA LMF
COMPUTER
To FRU MMI port
DB9–TO–DB25
ADAPTER
Figure 3-7: CDMA LMF Computer Common MMI Connections
COM1
OR
COM2
FW00687
3