User Manual
Bay Level Offset Calibration – continued
SC4812ET BTS Optimization/ATP — CDMA LMF
Jan 2002
3-94
Table 3-43: BTS TX Path Audit
Step Action
1 Select the BBX(s) to be audited.
NOTE
If STANDARD or CDF is selected for Test Pattern, then at least one MCC must be also selected.
2 From the Tests menu, select TX>TX Audit.
3 Select the appropriate carrier(s) displayed in the Channels/Carrier pick list.
Press and hold the <Shift> or <Ctrl> key to select multiple items.
4 Type the appropriate channel number in the Carrier n Channels box.
5 Select Verify BLO (default) or Single–sided BLO.
NOTE
Single–sided BLO is only used when checking non–redundant transceivers.
6 From the Test Pattern pick list, select a test pattern.
NOTE
Selecting PILOT (default) performs tests using a pilot signal only.
Selecting STANDARD performs tests using pilot, synch, paging and six traffic channels. This
requires an MCC to be selected.
Selecting CDFPILOT performs tests using the CDF value for pilot gain and IS–97 gain values
for all the other channels included in the Standard pattern setting (paging, synch, and six
traffic). Using this pattern setting requires the selection of both a BBX and at least one MCC.
Selecting CDF performs tests using pilot, synch, paging and six traffic channels, however, the
gain for the channel elements is specified in the CDF file.
7 Click on OK.
8 Follow the cable connection directions as they are displayed.
A status report window displays the test results.
9 Click on Save Results or Dismiss to close the status report window.
Exception Handling
In the event of a failure, the calibration procedure displays a FAIL
message in the status report window and provides information in the
Description field.
Recheck the test setup and connection and re–run the test. If the tests fail
again, note specifics about the failure, and refer to Chapter 6,
Troubleshooting.