Test Set Calibration continued
SC4812ET BTS Optimization/ATP CDMA LMF
Jan 2002
3-82
Setting Coupler Loss Value
If an inservice coupler is installed the coupler loss (e.g., 30 dB) must be
manually entered so it will be included in the LMF TX calibration and
audit calculations and the RX FER test.
Prerequisites
Logged into the BTS
Table 3-37: Setting Coupler Loss Values
Step Action
1 Click on the Util menu.
2 Select Edit >Coupler Loss>TX or RX. A data entry popup window will appear.
3 Click in the Loss (dBm) column for each carrier that has a coupler and enter the appropriate value.
4 To edit existing values click in the data box to be changed and change the value.
5 Click on the Save button to save displayed values.
6 Click on the Dismiss button to exit the window. Values that were entered/changed after the Save
button was used will not be saved.
NOTE
The InService Calibration check box in the Tools>Options>BTS Options tab must checked
before entered coupler loss values will be used by the TX calibration and audit functions or RX Fer
test.
Entered values will be used by the LMF as soon as they are saved. You do not have to logout and
login.