User's Manual
Power Delta Calibration68P09255A69-3
Aug 2002
1X SC4812ET Lite BTS Optimization/ATP Software Release 2.16.1.x
PRELIMINARY
H-7
Table H-2: Advantest R3267 Power Delta Calibration Procedure
Step Action
16 Record the Power Meter reading as result A________________________
17 On the R3562 CRT, set the Output to OFF by pressing ACTIVE key 6.
18 Connect the RF cable from R3562 signal generator RF OUT port to the R3267 spectrum analyzer
INPUT Port, refer to Figure H-5.
19 On the R3562 CRT, set the Output to ON by pressing ACTIVE key 6.
20 On the R3267, press the POWER key in the MEASUREMENT section of the control panel.
21 Press the LEVEL key in the ENTRY section of the control panel.
22 Set the REF LEVEL to 10 dBm using the keypad ENTRY section keys.
23 On the CRT, select dB/div by pressing ACTIVE key 1.
24 On the CRT, select 10 dB/div by pressing ACTIVE key 1.
25 Press the FREQ key in ENTRY section of the control panel.
26 Set the frequency to the desired value using the keypad ENTRY section keys.
27 On the CRT, select more 1/2 by pressing ACTIVE key 7.
28 Press the Preselector CRT menu key to highlight 3.66G.
29 Press the POWER key in the MEASUREMENT section of the control panel.
30 Press the SPAN key in the ENTRY section of the control panel.
31 On the CRT, select Zero Span by pressing ACTIVE key 2.
32 Press the COUPLE key in the ENTRY section of the control panel.
33 On the CRT, select RBW and highlight MNL by pressing ACTIVE key 3.
34 Set RBW to 30 kHz using keypad ENTRY section keys.
35 On the CRT, select VBW and highlight MNL by pressing ACTIVE key 2.
36 Set VBW to 1 MHz using keypad ENTRY section keys.
37 Press the MKR key in the DISPLAY CONTROL section of the control panel.
38 On the CRT, select Normal Marker by pressing ACTIVE key 1.
39 Record the Marker Level reading as result B________________________
40 Press Single in ENTRY section of control panel.
. . . continued on next page
H