User's Manual

Power Delta Calibration68P09255A69-3
Aug 2002
1X SC4812ET Lite BTS Optimization/ATP Software Release 2.16.1.x
PRELIMINARY
H-5
Table H-1: Agilent E4406A Power Delta Calibration Procedure
Step Action
13
Calculate the Power Calibration Delta value. The delta value is the power meter measurement minus
the Agilent measurement.
Delta = A - B
Example: Delta = -0.70 dBm - (-1.25 dBm) = 0.55 dBm
Example: Delta = 0.26 dBm - 0.55 dBm = -0.29 dBm
These examples are included to show the mathematics and do not represent actual readings.
NOTE
Add this delta value to the TX Cable Loss value during In-Service Calibration (see step 4 in
Table H-6).
Figure H-1: Delta Calibration Setup - Agilent E4432B to HP437
Power
Sensor
Agilent E4432B and E4406A
Short RF Cable
HP437B
SENSOR
RF OUTPUT
Figure H-2: Delta Calibration Setup - Agilent E4432B to Agilent E4406A
Short RF Cable
RF INPUT
Agilent E4432B and E4406A
RF OUTPUT
H